If your sparkling water is coming out of the tap flat it might be time to change your Co2 cylinder. First, check the regulator pressure gauge located on the canister to see where the needle is pointing. If it is down towards the left in the yellow zone, adjust the knob on the top of the bottle. If the needle doesn’t go back to the green zone then the cylinder will need to be changed.

Zenith part number 91295NZ (2 x canisters of 1000 grams of Co2). Note – Safety glasses gloves or a towel and care should be used when fitting or removing the regulator from the bottle.

If you are unsure about changing a Co2 cylinder, a qualified Zenith service technician would be happy to assist. Call 0800 558 055 to schedule an appointment.

Step 01: First you will need to turn the Co2 cylinder regulator off. Do this by twisting the knob anti-clockwise until it screws up and away from the bottle.

Step 02: Before removing the regulator from the bottle, start the Co2 purge to relieve any pressure in the Co2 line. On the screen menu select [Install] then [Co2 Purge], then [Start].

Step 03: Gas flow will start, then slow and stop. When gas flow has stopped, press [Stop]. You may leave the display in this mode.

Step 04: Remove the bottle from the cupboard and disconnect the regulator by unscrewing it from the bottle. The braided hose can be left attached to the regulator. If removal of the hose to regulator is required take care not to lose the plastic olive inside the braided hose.

Step 05: The regulator and hose assembly needs to be fitted to the new gas bottle. Do this by screwing the new regulator in place. Be aware some Co2 may be discharged from the cylinder as the regulator is attached and always make sure the bottle is upright.

Step 06: Slot the bottle back into place in an upright position securing it with the fixing strap.

Step 07: Turn the Co2 cylinder regulator on by twisting the knob slowly clockwise. Watch the needle on the gauge carefully and keep twisting the knob until the gauge indicates 3.0-bar, in the Green zone on the dial.

Step 08: It's important at this stage to check for gas leaks so take a soapy sponge and allow some soap suds to fall on the regulator fitting and hose. Watch carefully for any movement or increasing bubbles in suds that would indicate a leak. If you spot a leak, twist the knob back in an anti-clockwise direction (turning regulator off) and rectify leak. Wipe off suds and repeat the checking process.

If all ok proceed to next step. If further assistance is required please call ZENITH Customer Care on 0800 558 055.

Step 09: Next you need to purge the gas lines to ensure the new CO2 cylinder will work efficiently. If your screen is not showing the Co2 purge screen, press the [MENU] button to bring up the main menu. Press the [Install] button then press [Purge CO2].

Step 10: When the next screen comes up, press the [START] button. Water will begin to flow through the HydroTap. If a font is fitted, a bucket or bowl to catch water flow from tap may assist.

Step 11: When the water appears to have stopped flowing and only Co2 gas is escaping through the tap, wait another 10 seconds then press the [STOP] button to end the purge. Dispose of the purge water in the sink.

Step 12: Press the [back] button to go back to the previous menu or press [HOME] to return to the home screen.

Step 13: It's a good idea to dispense some sparkling water from the tap and perform a taste test. There may be a small burst of gas pressure when you perform this task but if you let the levers go then press again, the unit should work normally.

Step 14: Residential G4 HydroTap cylinders are non-refillable but can be recycled at most council recycling facility. Please do not place in council bin but dispose of thoughtfully. If a Zenith technician changes your cylinders, they will remove the old cylinder and recycle it for you.